Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
Repeatability and reproducibility of right ventricular Tei index valves derived from three echocardiographic methods
Abstract:
OBJECTIVE To evaluate repeatability and reproducibility of right ventricular Tei index (RTX) values derived from dual pulsed-wave Doppler, conventional pulsed-wave Doppler, and tissue Doppler echocardiography and to investigate relationships and repeatability among the 3 methods in healthy dogs. ANIMALS 6 healthy adult Beagles. PROCEDURE Echocardiography was performed on each dog on different days for 2 weeks (3 times/d) by 2 echocardiographers. Intraobserver within- and between-day and interobserver coefficients of variation (CVs) and intraclass correlation coefficients (ICCs) for RTXs derived from dual pulse-waved Doppler (RTXDPD), conventional pulsed-wave Doppler (RTXPD), and tissue Doppler (RTXTD) methods were determined. Degrees of agreement among RTX values derived from the 3 methods were assessed by modified Bland-Altman analysis. RESULTS Least squares mean (95% confidence interval) RTXtd was 0.50 (0.46 to 0.54), which was significantly higher than that for RTXDPD (0.27 [0.23 to 0.31]) and RTXPD (0.25 [0.21 to 0.29]). Agreement between RTXDPD and RTXPD was good (bias [mean difference], 0.04 [95% confidence interval, -0.03 to 0.10]). The RTXdpd had high within-day (CV, 6.1; ICC, 0.77) and interobserver (CV, 3.5; ICC, 0.83) repeatability, but between-day repeatability was not high. The RTXtd had high within-day repeatability (CV, 6.0; ICC, 0.80), but between-day and interobserver repeatability were not high. Within-day, between-day, and interobserver repeatability of RTXPD were not high. CONCLUSIONS AND CLINICAL RELEVANCE RTXdpd measurement was a repeatable and reproducible method of cardiac evaluation in healthy dogs. The RTXTD values were significantly higher than the RTXDPD and RTXPD values; therefore, RTX values derived from different echocardiographic methods should be interpreted with caution.
More Related Videos
06:04Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
Published on: April 27, 2019
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...