Risk Factors for Extubation Failure in Extremely Low Birth Weight Infants
Related Experiment Video
Updated: Mar 18, 2026

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Shih-Hsin Wang1, Jyun-You Liou2, Chien-Yi Chen2
1Department of Pediatrics, National Taiwan University Hospital Children's Hospital, Taipei, Taiwan; Department of Pediatrics, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
Insights
Extremely low birth weight infants needing mechanical ventilation have a high risk of extubation failure. Poor acid-base balance post-extubation, indicated by low pH and bicarbonate, predicts reintubation in these vulnerable neonates.
Area of Science:
- Neonatal Medicine
- Pediatric Critical Care
- Respiratory Physiology
Background:
- Neonatal respiratory distress syndrome (RDS) management has improved with antenatal steroids and nasal continuous positive airway pressure (NCPAP).
- However, intubation and mechanical ventilation remain common for extremely low birth weight (ELBW) infants.
- Optimal extubation timing for ELBW infants is not well-defined.
Purpose of the Study:
- To identify risk factors for extubation failure in extremely low birth weight infants.
- To determine predictors of reintubation in this high-risk neonatal population.
Main Methods:
- Retrospective analysis of ELBW infants admitted to a neonatal intensive care unit (NICU) from 2009-2013.
- Collection of demographic, ventilation, and arterial blood gas (ABG) data pre- and post-extubation.
- Definition of extubation failure as reintubation within 7 days; risk factors analyzed using univariate and multivariate logistic regression.
Main Results:
- Nearly half (55.5%) of ELBW infants in the cohort did not require intubation.
- Among intubated survivors, 23.5% experienced extubation failure (reintubation within 7 days).
- Lower post-extubation arterial pH (<7.3) and bicarbonate (<18 mM/L) were significant predictors of extubation failure (OR 4.56 and 6.187, respectively).
Conclusions:
- A significant proportion of ELBW infants can avoid intubation.
- Post-extubation acid-base status is a critical indicator for predicting extubation failure in ELBW infants.
- Monitoring pH and bicarbonate levels after extubation can help identify high-risk neonates requiring closer observation or intervention.
Background:
Although antenatal steroids and early use nasal continuous positive airway pressure (NCPAP) have significantly improved outcomes of neonatal respiratory distress syndrome, intubation with ventilator support is still commonly required in extremely low birth weight (ELBW) infants. The optimal timing of extubation in ELBW infants remains unclear.
Methods:
We retrospectively analyzed all ELBW preterm infants who were admitted to our neonatal intensive care unit (NICU) from January 2009 to December 2013. Demographic, ventilation, and arterial blood gas analysis results prior to and 2 hours after extubation were collected. Extubation failure was defined as reintubation due to deterioration of respiratory condition within 7 days after extubation. Risk factors for extubation failure were analyzed.
Results:
In total, 173 ELBW infants were born and admitted to our NICU during these 5 years. Among these 173 infants, 77 (44.5%) used NCPAP only during their hospitalization (20 diagnosed with chronic lung disease (CLD), 25.9%). Among the 95 patients that required intubation, 27 patients expired so extubation was not attempted. Sixteen of 68 (23.5%) survival cases required reintubation within 7 days after extubation. We found that gestational age, birth body weight, and sex ratio did not differ between the successful extubation group and the failed extubation group. Univariate analysis showed that the failed extubation group had a lower arterial pH right before and 2 hours after extubation, with a lower bicarbonate level after extubation. Further multivariate logistic regression analysis revealed an association between poor acid-base homeostasis 2 hours after extubation (pH < 7.3 and HCO3 < 18 mM/L) and extubation failure (odds ratio 4.56 and 6.187 and 95% confidence interval: 1.263∼16.462 and 1.68∼22.791, respectively).
Conclusion:
This study shows that nearly half of ELBW infants do not require intubation. Among ELBW infants who require invasive ventilator support, those who have lower postextubation arterial pH and bicarbonate levels are at high risk of extubation failure.
More Related Videos
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Pulmonary Cycle: Exhalation

