Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Transmitted irradiance through ceramics: effect on the mechanical properties of a luting resin cement
1Department of Operative/Restorative Dentistry, Periodontology and Pedodontics, Ludwig-Maximilians University of Munich, Goethestr. 70, 80336, Munich, Germany. nilie@dent.med.uni-muenchen.de.
Objectives:
The study aims to characterise the curing behaviour of a light-curing luting composite (Variolink® Aesthetic LC, Ivoclar Vivadent) polymerised at different exposure times (10 s, 20 s) through different ceramics (IPS Empress CAD and IPS e.max CAD, Ivoclar Vivadent) and ceramic thicknesses (no ceramic, 0.5, 1, 1.5 and 2 mm).
Material And Method:
Curing units' (Bluephase Style, Ivoclar Vivadent) variation in irradiance delivered up to 10-mm exposure distance as well as the incident and transmitted irradiance and radiant exposure up to 6-mm ceramic thickness were assessed on a laboratory-grade spectrometer. A total of 216 (18 groups, n = 12) thin and flat luting composite specimens of 500-μm thickness were prepared and stored after curing in a saturated vapour atmosphere for 24 h at 37 °C. Micro-mechanical properties (Vickers hardness, HV and indentation modulus, YHU) were determined by means of an automatic micro-hardness indenter.
Results:
Within the study design, the radiant exposure received by the luting composite varied from 2.56 to 24.75 J/cm2, showing a high impact on the measured properties. Comparing the effect of the parameters exposure time, ceramic thickness and type, the highest influence on the micro-mechanical parameters was identified for exposure time, while this influence was stronger on HV (p < 0.001, η P2 = 0.452) than on YHU (p < 0.001, η P2 = 0.178). The influence of ceramic type was significant but low (η P2 = 0.161 on HV and 0.113 on YHU), while the influence of ceramic thickness was the lowest (η P2 = 0.04 and 0.05, respectively).
Conclusions:
Slightly higher irradiance values were transmitted through Empress CAD up to a ceramic thickness of 3 mm (p < 0.001), while being comparable with e.max for thicker slices. Differences in translucency between ceramics were reflected in the micro-mechanical properties of the luting composite.
Clinical Relevance:
The radiant exposure reaching the luting composite is determined by the incident irradiance, exposure time, ceramic type and ceramic thickness. At the analysed incident irradiance, exposure time was the most consistent parameter affecting the micro-mechanical properties of the luting composite, and this effect was strongly reflected in the more translucent ceramic Empress CAD. Within the curing conditions, an exposure time of 20 s is recommended.
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Hydration of Cement
Fineness of Cement
Direct...
Accelerated Curing of Concrete
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...