Dilute versus concentrated vasopressin administration during laparoscopic myomectomy: a randomised controlled trial
S L Cohen1, S Senapati2, A R Gargiulo3
1Division of Minimally Invasive Gynecologic Surgery, Brigham and Women's Hospital, Boston, MA, USA.
Objective:
To determine if higher-volume, fixed-dose administration of vasopressin further reduces blood loss at the time of minimally invasive myomectomy.
Design:
Randomised multicentre clinical trial.
Setting:
Tertiary-care academic centres in the USA.
Population:
Women undergoing conventional laparoscopic or robot-assisted laparoscopic myomectomy.
Methods:
All participants received the same 10-unit (U) dose of vasopressin, but were randomly assigned to one of two groups: (i) received 200 ml of diluted vasopressin solution (20 U in 400 ml normal saline), and (ii) received 30 ml of concentrated vasopressin solution (20 U in 60 ml normal saline).
Main Outcome Measures:
The primary study outcome was estimated blood loss; the study was powered to detect a 100-ml difference.
Results:
A total of 152 women were randomised; 76 patients in each group. Baseline demographics were similar between groups. The primary outcome of intraoperative blood loss was not significantly different, as measured by three parameters: surgeon estimate (mean estimated blood loss 178 ± 265 ml and 198 ± 232 ml, dilute and concentrated groups respectively, P = 0.65), suction canister-calculated blood loss, or change in haematocrit levels. There were no vasopressin-related adverse events.
Conclusion:
Both dilute and concentrated vasopressin solutions that use the same drug dosing demonstrate comparable safety and tolerability when administered for minimally invasive myomectomy; however, higher volume administration of vasopressin does not reduce blood loss.
Tweetable Abstract:
This randomised trial failed to show benefit of high-volume dilute vasopression.