Related Experiment Video
Updated: Mar 18, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
A methodological approach for quantifying and characterizing the stability of agitated saline contrast: implications
Heather K Hackett1, Lindsey M Boulet1, Paolo B Dominelli2
1Centre for Heart, Lung, and Vascular Health, School of Health and Exercise Science, University of British Columbia, Kelowna, British Columbia, Canada; and.
Abstract:
Agitated saline contrast echocardiography is often used to determine blood flow through intrapulmonary arteriovenous anastomoses (Q̇IPAVA). We applied indicator dilution theory to time-acoustic intensity curves obtained from a bolus injection of hand-agitated saline contrast to acquire a quantitative index of contrast mass. Using this methodology and an in vitro model of the pulmonary circulation, the purpose of this study was to determine the effect of transit time and gas composition [air vs. sulphur hexafluoride (SF6)] on contrast conservation between two detection sites separated by a convoluted network of vessels. We hypothesized that the contrast lost between the detection sites would increase with transit times and be reduced by using contrast bubbles composed of SF6 Changing the flow and/or reducing the volume of the circulatory network manipulated transit time. Contrast conservation was measured as the ratio of outflow and inflow contrast masses. For air, 53.2 ± 3.4% (SE) of contrast was conserved at a transit time of 9.25 ± 0.02 s but dropped to 16.0 ± 1.0% at a transit time of 10.17 ± 0.06 s. Compared with air, SF6 contrast conservation was significantly greater (P < 0.05) with 114.3 ± 2.9% and 73.7 ± 3.3% of contrast conserved at a transit time of 10.39 ± 0.02 s and 13.46 ± 0.04 s, respectively. In summary, time-acoustic intensity curves can quantify agitated saline contrast, but loss of contrast due to bubble dissolution makes measuring Q̇IPAVA across varying transit time difficult. Agitated saline composed of SF6 is stabilized and may be a suitable alternative for Q̇IPAVA measurement.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021