Ultrasonography01:17

Ultrasonography

8.3K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
8.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Racial and ethnic disparities in esophageal cancer survival are greatest at curable stages: a population-based study.

Cancer causes & control : CCC·2026
Same author

A randomized controlled study to compare the efficacy of intravitreal faricimab 6.0 mg versus aflibercept 2.0 mg in management of treatment-naive diabetic macular edema in Indian populations.

Indian journal of ophthalmology·2026
Same author

Ultrawide-field indocyanine angiography changes post 12 weeks of eplerenone in central serous chorioretinopathy.

Indian journal of ophthalmology·2026
Same authorSame journal

Epithelial ingrowth post small incision lenticule extraction: CIRCLE software to the rescue.

Medical journal, Armed Forces India·2026
Same author

Demarcation line following additive stromal keratoplasty.

Eye (London, England)·2026
Same author

Outcomes of blepharoplasty for orbital fat prolapse in thyroid eye disease: a clinical study.

International ophthalmology·2026

Related Experiment Video

Updated: Mar 18, 2026

Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
07:44

Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy

Published on: April 27, 2016

10.2K

Ultrasonic pachymeter: a little different role.

Alok Sati1, Deepak Kalra2, Rakesh Maggon3

  • 1Graded Specialist (Ophthalmology), Military Hospital, Secunderabad, Andhra Pradesh.

Medical Journal, Armed Forces India
|July 2, 2016
PubMed
Summary

Phacoemulsification leads to the quickest corneal thickness recovery after cataract surgery compared to SICS and ECCE. Ultrasonic pachymetry effectively tracks these changes, aiding in visual rehabilitation assessments.

Keywords:
ECCESICScorneal thicknessphacoemulsificationultrasonic pachymeter

More Related Videos

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
04:54

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging

Published on: June 16, 2023

3.9K
Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
09:21

Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer

Published on: September 28, 2015

13.1K

Related Experiment Videos

Last Updated: Mar 18, 2026

Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
07:44

Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy

Published on: April 27, 2016

10.2K
Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
04:54

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging

Published on: June 16, 2023

3.9K
Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
09:21

Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer

Published on: September 28, 2015

13.1K

Area of Science:

  • Ophthalmology
  • Biomedical Engineering

Background:

  • Ultrasonic pachymetry is utilized beyond refractive surgery and glaucoma evaluation.
  • It can assess corneal thickness changes after various cataract extraction methods.

Purpose of the Study:

  • To compare the changes in corneal thickness following three cataract surgery techniques: extracapsular cataract extraction (ECCE), small incision cataract surgery (SICS), and phacoemulsification.
  • To evaluate the role of ultrasonic pachymetry in monitoring postoperative corneal healing.

Main Methods:

  • A study involving 600 patients divided into three groups (200 eyes each) undergoing ECCE, SICS, or phacoemulsification.
  • Corneal thickness was measured using ultrasonic pachymetry pre-operatively and on days 1, 2, 7, 15, and 30 postoperatively.

Main Results:

  • Pre-operative mean central corneal thickness was 525.35 ± 32.34 μm.
  • Postoperative corneal thickness significantly increased, with recovery to pre-operative levels achieved earliest with phacoemulsification (by day 2), followed by SICS (by day 7), and ECCE (by day 15) in the central cornea.
  • Similar trends were observed in other quadrants, with the inferior cornea showing rapid recovery by day 2 across all techniques.

Conclusions:

  • Phacoemulsification facilitates the earliest visual rehabilitation and corneal thickness normalization post-surgery.
  • Inferior cornea exhibits the greatest thickness at the mid-periphery.
  • Ultrasonic pachymetry is a valuable tool for monitoring corneal healing and visual recovery after cataract surgery.