Related Experiment Video
Updated: Mar 18, 2026

Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
Interrater and intrarater reliability of the Knosp scale for pituitary adenoma grading
Michael A Mooney1, Douglas A Hardesty1, John P Sheehy1
1Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona.
Abstract:
OBJECTIVE The goal of this study was to determine the interrater and intrarater reliability of the Knosp grading scale for predicting pituitary adenoma cavernous sinus (CS) involvement. METHODS Six independent raters (3 neurosurgery residents, 2 pituitary surgeons, and 1 neuroradiologist) participated in the study. Each rater scored 50 unique pituitary MRI scans (with contrast) of biopsy-proven pituitary adenoma. Reliabilities for the full scale were determined 3 ways: 1) using all 50 scans, 2) using scans with midrange scores versus end scores, and 3) using a dichotomized scale that reflects common clinical practice. The performance of resident raters was compared with that of faculty raters to assess the influence of training level on reliability. RESULTS Overall, the interrater reliability of the Knosp scale was "strong" (0.73, 95% CI 0.56-0.84). However, the percent agreement for all 6 reviewers was only 10% (26% for faculty members, 30% for residents). The reliability of the middle scores (i.e., average rated Knosp Grades 1 and 2) was "very weak" (0.18, 95% CI -0.27 to 0.56) and the percent agreement for all reviewers was only 5%. When the scale was dichotomized into tumors unlikely to have intraoperative CS involvement (Grades 0, 1, and 2) and those likely to have CS involvement (Grades 3 and 4), the reliability was "strong" (0.60, 95% CI 0.39-0.75) and the percent agreement for all raters improved to 60%. There was no significant difference in reliability between residents and faculty (residents 0.72, 95% CI 0.55-0.83 vs faculty 0.73, 95% CI 0.56-0.84). Intrarater reliability was moderate to strong and increased with the level of experience. CONCLUSIONS Although these findings suggest that the Knosp grading scale has acceptable interrater reliability overall, it raises important questions about the "very weak" reliability of the scale's middle grades. By dichotomizing the scale into clinically useful groups, the authors were able to address the poor reliability and percent agreement of the intermediate grades and to isolate the most important grades for use in surgical decision making (Grades 3 and 4). Authors of future pituitary surgery studies should consider reporting Knosp grades as dichotomized results rather than as the full scale to optimize the reliability of the scale.
More Related Videos
07:43Endoscopic Endonasal Trans-sphenoidal Approach: Minimally Invasive Surgery for Pituitary Adenomas
Published on: January 17, 2018
12:50Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014