Incremental change in cross sectional area in small endotracheal tubes: A call for more size options
Caroline L Mortelliti1, Anthony J Mortelliti2
1Colgate University, Hamilton, NY, USA.
Objective:
To elucidate the relatively large incremental percent change (IPC) in cross sectional area (CSA) in currently available small endotracheal tubes (ETTs), and to make recommendation for lesser incremental change in CSA in these smaller ETTs, in order to minimize iatrogenic airway injury.
Methods:
The CSAs of a commercially available line of ETTs were calculated, and the IPC of the CSA between consecutive size ETTs was calculated and graphed. The average IPC in CSA with large ETTs was applied to calculate identical IPC in the CSA for a theoretical, smaller ETT series, and the dimensions of a new theoretical series of proposed small ETTs were defined.
Results:
The IPC of CSA in the larger (5.0-8.0 mm inner diameter (ID)) ETTs was 17.07%, and the IPC of CSA in the smaller ETTs (2.0-4.0 mm ID) is remarkably larger (38.08%). Applying the relatively smaller IPC of CSA from larger ETTs to a theoretical sequence of small ETTs, starting with the 2.5 mm ID ETT, suggests that intermediate sizes of small ETTs (ID 2.745 mm, 3.254 mm, and 3.859 mm) should exist.
Conclusion:
We recommend manufacturers produce additional small ETT size options at the intuitive intermediate sizes of 2.75 mm, 3.25 mm, and 3.75 mm ID in order to improve airway management for infants and small children.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...