Related Experiment Video
Updated: Mar 18, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Influence of Coronary Artery Diameter on Intracoronary Transluminal Attenuation Gradient During CT Angiography
Eun-Ah Park1, Whal Lee1, Sang Joon Park1
1Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
Objectives:
The goal of this study was to assess the effect of coronary artery diameter on luminal attenuation and the correlation between the transluminal attenuation gradient (TAG) and transluminal diameter gradient (TDG) on computed tomography (CT) coronary angiography.
Background:
Recent studies have reported promising results of TAG in detecting significant stenosis. However, because of the intrinsic nature of CT reconstruction algorithms, luminal attenuation may be affected by vessel diameter.
Methods:
In this 3-part study, phantom simulating vessels of various diameters immersed in different contrast mixtures were scanned, and intraluminal attenuations were measured. In addition, dynamic volume CT scanning was performed in 3 mongrel dogs (untreated, a stenosis model, and an occlusion model) using 320-row area detector computed tomography and intraluminal attenuations, and TAGs were calculated at each temporal scan and compared. In a separate clinical study, TAGs and TDGs of 152 coronary arteries from 62 patients who underwent 320-row area detector computed tomography coronary angiography and invasive angiography were measured and compared.
Results:
Intraluminal attenuation of phantom vessels gradually decreased along with a decrease in diameter. Animal studies revealed that the peak attenuation of distal smaller coronary arteries did not reach that of proximal larger coronary arteries: 55.2% to 78.1% peak attenuation of proximal coronary arteries. No differences in TAG were found between stenotic and normal left circumflex arteries at temporal scans (all, p > 0.05). The clinical study demonstrated significant correlation between TAG and TDG (r = 0.580; p < 0.0001).
Conclusions:
Intraluminal attenuation was shown to decrease with diminution of vessel diameters. In addition, TAG exhibited a significant correlation with TDG, implying that TAG may be a secondary result because of differences in diameters.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...