Related Experiment Video
Updated: Mar 18, 2026

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
The Influence of Humidity on Assessing Irritation Threshold of Ammonia
Christian Monsé1, Kirsten Sucker1, Frank Hoffmeyer1
1Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr-University Bochum (IPA), Bürkle-de-la-Camp-Platz 1, 44789 Bochum, Germany.
Abstract:
A large number of occupational exposure limit values (OELs) are based on avoiding of sensory irritation of the eyes and the upper respiratory tract. In order to investigate the chemosensory effect range of a chemical, odor and sensory irritation thresholds (lateralization thresholds, LTs) can be assessed. Humidity affects olfactory function and thus influences odor thresholds; however, a similar effect has not been shown for sensory irritation thresholds. The purpose of the present study was to explore whether LTs for ammonia vapor vary depending on the water vapor content of the inspired stimulus. Eight healthy nonsmoking volunteers were simultaneously exposed to ammonia vapor through one nostril and clean air through the other and were asked to determine which nostril received the chemical. Within experimental runs, ascending ammonia concentrations (60-350 ppm) that were either dry or humidified were administered at fixed time intervals. Geometric mean LTs obtained at wet (181 ppm) or dry (172 ppm) conditions did not differ significantly (P = 0.19) and were within the range of those reported by previous studies. These results suggest that humidity is not a critical factor in determining sensory irritation thresholds for ammonia, and future studies will examine if these findings are transferable to sensory irritation thresholds for other chemicals.
More Related Videos
Related Concept Videos
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Common Ion Effect
Weak Base Solutions
Physical Properties of Amines
Basicity of Heterocyclic Aromatic Amines
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):