Software-based PET-MR image coregistration: combined PET-MRI for the rest of us!
Matthew S Robertson1, Xinyang Liu1, William Plishker2
1Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan Ave. NW, Washington, DC, 20010, USA.
Background:
With the introduction of hybrid positron emission tomography/magnetic resonance imaging (PET/MRI), a new imaging option to acquire multimodality images with complementary anatomical and functional information has become available. Compared with hybrid PET/computed tomography (CT), hybrid PET/MRI is capable of providing superior anatomical detail while removing the radiation exposure associated with CT. The early adoption of hybrid PET/MRI, however, has been limited.
Objective:
To provide a viable alternative to the hybrid PET/MRI hardware by validating a software-based solution for PET-MR image coregistration.
Materials And Methods:
A fully automated, graphics processing unit-accelerated 3-D deformable image registration technique was used to align PET (acquired as PET/CT) and MR image pairs of 17 patients (age range: 10 months-21 years, mean: 10 years) who underwent PET/CT and body MRI (chest, abdomen or pelvis), which were performed within a 28-day (mean: 10.5 days) interval. MRI data for most of these cases included single-station post-contrast axial T1-weighted images. Following registration, maximum standardized uptake value (SUVmax) values observed in coregistered PET (cPET) and the original PET were compared for 82 volumes of interest. In addition, we calculated the target registration error as a measure of the quality of image coregistration, and evaluated the algorithm's performance in the context of interexpert variability.
Results:
The coregistration execution time averaged 97±45 s. The overall relative SUVmax difference was 7% between cPET-MRI and PET/CT. The average target registration error was 10.7±6.6 mm, which compared favorably with the typical voxel size (diagonal distance) of 8.0 mm (typical resolution: 0.66 mm × 0.66 mm × 8 mm) for MRI and 6.1 mm (typical resolution: 3.65 mm × 3.65 mm × 3.27 mm) for PET. The variability in landmark identification did not show statistically significant differences between the algorithm and a typical expert.
Conclusion:
We have presented a software-based solution that achieves the many benefits of hybrid PET/MRI scanners without actually needing one. The method proved to be accurate and potentially clinically useful.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging