Related Experiment Video
Updated: Mar 18, 2026

Non-invasive Skeletal Muscle Quantification in Small Animals Using Micro-computed Tomography
Published on: November 8, 2024
Thyroarytenoid muscle uptake and attenuation in PET/CT in elderly
Georges Ziade1, Sahar Semaan2, Ghina Fakhri2,3
1Department of Otolaryngology-Head and Neck Surgery, American University of Beirut Medical Centre, P.O.Box: 110236, Beirut, Lebanon.
Abstract:
The objective of this study is to compare uptake and attenuation on positron emission tomography/computed tomography (PET/CT) imaging modality at the thyroarytenoid muscle between subjects aged less and older than 65 years old. The study design is retrospective chart review. The setting is academic medical center. PET/CT images of 60 patients aged less than 65 years old and 60 patients aged more than 65 years old were selected. Demographic data were collected. Both the groups were compared with respect to the maximum standardized uptake value (SUV max) and CT attenuation of bilateral thyroarytenoid muscles. The mean SUV max of the right thyroarytenoid muscle was 2.09 ± 0.8 in the group of patients aged less than 65 years old compared to 1.9 ± 0.6 in the group of patients aged more than 65 years old. For the left thyroarytenoid muscle, the mean SUV max in the first and second groups was, respectively, 2 ± 0.6 and 1.9 ± 0.6. The differences were not statistically significant. As for the CT attenuation, the mean value at the right thyroarytenoid muscle in the first and second groups was, respectively, 31.2 ± 0.8 HU and 20.8 ± 14.4 HU (p < 0.05). At the left thyroarytenoid muscle, the mean value was, respectively, 29.6 ± 9.9 and 22.8 ± 15 (p < 0.05). This study suggests that CT attenuation measurements can be used for objectively assessing the change in the density of aging thyroarytenoid muscle.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography