Related Experiment Video
Updated: Mar 18, 2026

Analysis of SEC-SAXS data via EFA deconvolution and Scatter
Published on: January 28, 2021
Quantitative interpretation of molecular dynamics simulations for X-ray photoelectron spectroscopy of aqueous
Giorgia Olivieri1, Krista M Parry2, Cedric J Powell3
1Laboratory for Surface Science and Technology, Department of Materials, ETH Zürich, CH-8093 Zürich, Switzerland.
Abstract:
Over the past decade, energy-dependent ambient pressure X-ray photoelectron spectroscopy(XPS) has emerged as a powerful analytical probe of the ion spatial distributions at the vapor (vacuum)-aqueous electrolyteinterface. These experiments are often paired with complementary molecular dynamics (MD) simulations in an attempt to provide a complete description of the liquidinterface. There is, however, no systematic protocol that permits a straightforward comparison of the two sets of results. XPS is an integrated technique that averages signals from multiple layers in a solution even at the lowest photoelectron kinetic energies routinely employed, whereas MD simulations provide a microscopic layer-by-layer description of the solution composition near the interface. Here, we use the National Institute of Standards and Technology database for the Simulation of Electron Spectra for Surface Analysis (SESSA) to quantitatively interpret atom-density profiles from MD simulations for XPS signal intensities using sodium and potassium iodide solutions as examples. We show that electron inelastic mean free paths calculated from a semi-empirical formula depend strongly on solution composition, varying by up to 30% between pure water and concentrated NaI. The XPS signal thus arises from different information depths in different solutions for a fixed photoelectron kinetic energy. XPS signal intensities are calculated using SESSA as a function of photoelectron kinetic energy (probe depth) and compared with a widely employed ad hoc method. SESSA simulations illustrate the importance of accounting for elastic-scattering events at low photoelectron kinetic energies (<300 eV) where the ad hoc method systematically underestimates the preferential enhancement of anions over cations. Finally, some technical aspects of applying SESSA to liquidinterfaces are discussed.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Determination of Crystal Structures
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Molecular Spectroscopy: Absorption and Emission

