Related Experiment Video
Updated: Mar 18, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Effects of computational phantoms on the effective dose and two-dosimeter algorithm for external photon beams
K Karimi-Shahri1, L Rafat-Motavalli1, H Miri-Hakimabad1
1Ferdowsi University of Mashhad, Physics Department, School of Sciences, Mashhad, Iran.
Computational phantoms significantly impact effective dose (E) and dosimeter responses for external photon beams. A single two-dosimeter algorithm can be applied across various reference phantoms, simplifying dose estimation.
Area of Science:
- Medical Physics
- Radiation Dosimetry
- Computational Modeling
Background:
- Accurate external radiation dose assessment is crucial for radiation protection.
- Computational phantoms are essential tools for simulating radiation interactions within the human body.
- Variations in phantom design can influence calculated radiation doses and dosimeter responses.
Purpose of the Study:
- To investigate the influence of different computational phantoms on effective dose (E) and dosimeter responses.
- To evaluate the performance of a two-dosimeter algorithm across various reference phantoms.
- To determine the feasibility of using a universal algorithm for dose estimation.
Main Methods:
- Utilized Korean Typical MAN-2 (KTMAN-2), Chinese Reference Adult Male (CRAM), ICRP male reference, and Male Adult meSH (MASH) phantoms.
- Performed Monte Carlo simulations (MCNP code) for external photon beams at 0.08, 0.3, and 1 MeV.
- Analyzed dosimeter responses on phantom front and back, and assessed effective dose (E) and estimated dose (Eest).
Main Results:
- Phantom body shape significantly affects effective dose (E) and two-dosimeter responses during indirect irradiation.
- Two-dosimeter algorithms showed consistency across phantoms, with minor variations noted for KTMAN-2.
- Estimated dose (Eest) was overestimated in overhead (OH) and underfoot (UF) directions compared to calculated E.
- A single algorithm demonstrated applicability across all reference phantoms.
Conclusions:
- Computational phantom selection is a critical factor in external photon beam dosimetry.
- A generalized two-dosimeter algorithm can be effectively applied to different male reference phantoms.
- This finding supports the potential for simplified and standardized dose assessment protocols.