Related Experiment Video
Updated: Mar 18, 2026

Digital Home-Monitoring of Patients after Kidney Transplantation: The MACCS Platform
Published on: April 12, 2021
Monitoring high-risk patients: minimally invasive and non-invasive possibilities
Jochen Renner1, Matthias Grünewald1, Berthold Bein2
1Department of Anaesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein, Campus Kiel, Germany.
Abstract:
Over the past decades, there has been considerable progress in the field of less invasive haemodynamic monitoring technologies. Substantial evidence has accumulated, which supports the continuous measurement and optimization of flow-based variables such as stroke volume, that is, cardiac output, in order to prevent occult hypoperfusion and consequently to improve patients' outcome in the perioperative setting. However, there is a striking gap between the developments in haemodynamic monitoring and the increasing evidence to implement defined treatment protocols based on the measured variables, and daily clinical routine. Recent trials have shown that perioperative morbidity and mortality is higher than anticipated. This emphasizes the need for the anaesthesia community to address this issue and promotes the implementation of proven concepts into clinical practice in order to improve patients' outcome, especially in high-risk patients. The advances in minimally invasive and non-invasive monitoring techniques can be seen as a driving force in this respect, as the degree of invasiveness of any monitoring tool determines the frequency of its application, especially in the operating room (OR). From this point of view, we are very confident that some of these minimally invasive and non-invasive haemodynamic monitoring technologies will become an inherent part of our monitoring armamentarium in the OR and in the intensive care unit (ICU).
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:24A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Rheumatic Heart Disease IV: Nursing Management
Errors occurring during blood pressure monitoring
Several factors...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...