Related Experiment Video
Updated: Mar 18, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Ultrasonic Technology Improves Radial Artery Puncture and Cannulation in Intensive Care Unit (ICU) Shock Patients
Xiuyan Li1, Guizhen Fang2, Danhua Yang3
1Department of Intensive Care Unit (ICU), The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China (mainland).
Abstract:
BACKGROUND This study observed the efficacy of ultrasonic technique with out-of-plane orientation and in-plane guidance in radial artery puncture and cannulation in intensive care unit (ICU) shock patients to elucidate the effect of this technique on the security of cannulation. MATERIAL AND METHODS A total of 88 ICU shock patients, randomized into a palpation (control) group and an ultrasound (experimental) group, received continuous intravenous sedation and analgesia. The palpation group patients underwent radial artery cannulation using the traditional palpation pulsation approach, and the ultrasound group patients underwent radial artery cannulation under out-of-plane orientation and in-plane guidance using an ultrasonic apparatus. Data were recorded and compared between the 2 groups. RESULTS (1) The success rate of the first puncture in the ultrasound group and the palpation group was 80% and 42%, respectively (P<0.05). (2) The cannulation duration in the ultrasound group and the palpation group was 8.77±6.33 s and 28.7±26.33 s, respectively (P<0.01). (3) Incidence of hematoma and staxis around stoma in the ultrasound group was 2.5% and 5%, respectively, which was significantly lower than that in the palpation group, which was 20% and 32.5%, respectively (P<0.05). (4) Time to achieve the early goal-directed therapy in the ultrasound group and the palpation group was 306.73±39.98 min and 356.75±40.97 min, respectively (P<0.01). CONCLUSIONS Compared with the traditional method, radial artery cannulation with out-of-plane orientation and in-plane guidance is a quick and secure cannulation method and is appropriate for use in clinics.
More Related Videos
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation