Information or resolution: Which is required from an SEM to study bulk inorganic materials?
1Ames Laboratory, Division of Materials Sciences and Engineering, Ames, Iowa.
Scanning
|July 12, 2016
Summary
Selecting the right scanning electron microscope (SEM) is crucial for bulk inorganic materials research. This guide helps researchers choose an SEM based on imaging needs, performance, and ease of use.
Area of Science:
- Materials Science
- Analytical Chemistry
- Physics
Background:
- Scanning Electron Microscopy (SEM) has advanced significantly, with diverse functionalities and performance levels impacting research outcomes.
- Bulk inorganic materials research requires SEMs capable of providing quantitative composition, orientation, and detailed imaging of chemistry, structure, and topography.
Approach:
- This work provides perspectives on selecting an SEM, emphasizing the interplay between the electron optical column, detection systems, and practical operating parameters.
- Key factors include probe performance, signal-to-noise ratio, spatial resolution, and the SEM's ability to integrate accessories like energy-dispersive spectrometers and electron backscatter diffraction detectors.
Key Points:
- The electron optical column dictates probe performance, while detection systems convert signal electrons into imaging data.
- Controllable parameters such as probe size/current, acceleration voltage, and detector selection are critical for optimal imaging.
- The SEM platform's design, including the specimen chamber and stage, significantly influences accessory performance and overall functionality.
Conclusions:
- Selecting an appropriate SEM involves assessing imaging capabilities, system integration, ease of use, and maintenance.
- Proper specimen selection, imaging condition design, and analysis of chamber geometry are vital for performance evaluation.
- Stable software and user-friendly interfaces enhance the usability of computer-controlled SEM systems for materials research.
Related Concept Videos
Scanning Electron Microscopy
5.9K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
5.9K
Overview of Electron Microscopy
16.2K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
16.2K
Overview of Microscopy Techniques
17.6K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
17.6K
Preparation of Samples for Electron Microscopy
7.6K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
7.6K