Radiologist variability in assessing the position of the cavoatrial junction on chest radiographs
Tze Y Chan1, Andrew England2, Sara M Meredith1
11 Department of Radiology, Royal Liverpool University Hospital NHS Trust, Liverpool, UK.
Objective:
To assess the variability in identifying the cavoatrial junction (CAJ) on chest X-rays (CXRs) amongst radiologists.
Methods:
23 radiologists (13 consultants and 10 trainees) assessed 25 posteroanterior erect CXRs (including 8 duplicates) and marked the positions of the CAJ. Differences in the CAJ position both within and between observers were evaluated and reported as limits of agreement (LOA), repeatability coefficients (RCs) and intraclass correlation coefficients and were displayed graphically with Bland-Altman plots.
Results:
The mean difference for within-observer assessments was -0.2 cm (95% LOA, -1.5 to +1.1 cm) and between observers, it was -0.3 cm (95% LOA, -2.5 to +1.8 cm). Intraobserver RCs were marginally lower for consultants than for trainees (1.1 vs 1.5). RCs between observers were comparable (2.1 vs 2.2) for consultants and trainees, respectively.
Conclusion:
This study detected a large interobserver variability of the CAJ position (up to 4.3 cm). This is a significant finding considering that the length of the superior vena cava is reported to be approximately 7 cm. We conclude that there is poor consensus regarding the CAJ position amongst radiologists.
Advances In Knowledge:
No comparisons exist between radiologists in determining CAJ position from CXRs. This report provides evidence of the large observer variability amongst radiologists and adds to the discussion regarding the use of CXRs in validating catheter tip location systems.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Location and Orientation of the Heart