Related Experiment Video
Updated: Mar 18, 2026

High Throughput Analysis of Liquid Droplet Impacts
Published on: March 6, 2020
An Impact Velocity Device Design for Blood Spatter Pattern Generation with Considerations for High-Speed Video
Theresa Stotesbury1, Mike Illes1,2, Andrew J Vreugdenhil1
1Materials Science Graduate Program, Trent University, 1600 West Bank Drive, Peterborough, ON, Canada, K9J 7B8.
Abstract:
A mechanical device that uses gravitational and spring compression forces to create spatter patterns of known impact velocities is presented and discussed. The custom-made device uses either two or four springs (k1 = 267.8 N/m, k2 = 535.5 N/m) in parallel to create seventeen reproducible impact velocities between 2.1 and 4.0 m/s. The impactor is held at several known spring extensions using an electromagnet. Trigger inputs to the high-speed video camera allow the user to control the magnet's release while capturing video footage simultaneously. A polycarbonate base is used to allow for simultaneous monitoring of the side and bottom views of the impact event. Twenty-four patterns were created across the impact velocity range and analyzed using HemoSpat. Area of origin estimations fell within an acceptable range (ΔXav = -5.5 ± 1.9 cm, ΔYav = -2.6 ± 2.8 cm, ΔZav = +5.5 ± 3.8 cm), supporting distribution analysis for the use in research or bloodstain pattern training. This work provides a framework for those interested in developing a robust impact device.