Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Comparative analysis of phytochemical traits, proximate composition, and metabolite diversity in Nigella sativa L. genotypes from India.

Scientific reports·2026
Same author

Multi-enzyme producing lignocellulolytic bacteria from biogas slurry: molecular identification and optimization of enzyme production by Bacillus subtilis BCA-1.

Brazilian journal of microbiology : [publication of the Brazilian Society for Microbiology]·2026
Same author

Correction: A novel proposed classification system for rock slope stability assessment.

Scientific reports·2026
Same author

Efficacy of aniseed essential oil as natural preservative in meat emulsion at refrigeration temperature.

British poultry science·2026
Same author

Development of a history-taking form for mesothelioma patients at risk of exposure to asbestos.

Public health action·2025
Same author

Drip fertigation improves cumin productivity, essential oil content, water use efficiency and profitability in arid zones of Rajasthan.

Scientific reports·2025
Same journal

Tuberculosis verrucosa cutis: An easy spotter yet frequently missed!

Medical journal, Armed Forces India·2026
Same journal

Non-Hodgkin lymphoma arising in a vallecular cyst: A rare clinical entity.

Medical journal, Armed Forces India·2026
Same journal

Utility of pre-operative magnetic resonance imaging (pelvis and abdomen) and combined tumour markers HE4 and CA125 in diagnosing early and advanced carcinoma endometrium.

Medical journal, Armed Forces India·2026
Same journal

Endoscopic management of Zenker's diverticulum.

Medical journal, Armed Forces India·2026
Same journal

Epithelial ingrowth post small incision lenticule extraction: CIRCLE software to the rescue.

Medical journal, Armed Forces India·2026
Same journal

Colistin rapid NP test for detection of colistin-resistance in colistin-resistant enterobacterales.

Medical journal, Armed Forces India·2026
See all related articles

Related Experiment Video

Updated: Mar 18, 2026

Antigens Protected Functional Red Blood Cells By The Membrane Grafting Of Compact Hyperbranched Polyglycerols
11:31

Antigens Protected Functional Red Blood Cells By The Membrane Grafting Of Compact Hyperbranched Polyglycerols

Published on: January 2, 2013

18.5K

Comparative Study of Blood Cross Matching Using Conventional Tube and Gel Method.

D Swarup1, P S Dhot2, J Kotwal3

  • 1Commanding Officer, 302 Fd Amb, (Ex Classified Specialist (Pathology), AFTC Delhi Cantt-110010).

Medical Journal, Armed Forces India
|July 14, 2016
PubMed
Summary
This summary is machine-generated.

The gel method offers a faster and more reliable alternative for blood compatibility testing compared to the conventional tube method. This technique enhances efficiency in transfusion medicine without compromising accuracy.

Keywords:
Compatibility testingID gel technique

More Related Videos

Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels
10:57

Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels

Published on: August 3, 2009

42.1K
Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
09:07

Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles

Published on: May 24, 2024

1.5K

Related Experiment Videos

Last Updated: Mar 18, 2026

Antigens Protected Functional Red Blood Cells By The Membrane Grafting Of Compact Hyperbranched Polyglycerols
11:31

Antigens Protected Functional Red Blood Cells By The Membrane Grafting Of Compact Hyperbranched Polyglycerols

Published on: January 2, 2013

18.5K
Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels
10:57

Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels

Published on: August 3, 2009

42.1K
Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
09:07

Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles

Published on: May 24, 2024

1.5K

Area of Science:

  • Transfusion Medicine
  • Clinical Pathology
  • Immunoserology

Background:

  • Conventional tube method is the standard for blood compatibility and crossmatching.
  • Accurate pre-transfusion testing is critical for patient safety.

Purpose of the Study:

  • To compare the efficacy of the conventional tube method and the gel technique for compatibility testing.
  • To evaluate the gel method as a potential replacement for the spin tube method.

Main Methods:

  • A comparative study involving 1000 blood samples.
  • Compatibility testing performed using both conventional tube and DiaMed gel methods.
  • Analysis of results from both techniques.

Main Results:

  • The gel method demonstrated rapid and reliable results.
  • No wash phase was required for the indirect antiglobulin test using the gel method.
  • Sensitivity and specificity of the gel method were comparable to the spin tube method.

Conclusions:

  • The gel method is a superior substitute for the conventional spin tube method in compatibility testing.
  • The gel technique offers advantages in speed and reliability.