Percutaneous Closure of Perimembranous Ventricular Septal Defect with Amplatzer Device
P Bharadwaj1, A Banerji1, R Datta1
1Senior Advisor (Medicine & Cardiology), MH (CTC), Pune.
Background:
The Amplatzer perimembranous ventricular septal occluder is an innovative device for percutaneous closure of perimembranous ventricular septal defects (PMVSD). In appropriately selected cases this procedure is safe and effective.
Methods:
Fourteen patients with the mean age 10.53 years (range 18 months to 55 years) and mean body weight 20.64 kg (range 6 to 52 kg) underwent PMVSD closure.
Result:
The PMVSD mean diameter was 5.28 mm (range from 4 to 9 mm). Implantation was successful in 92% of the cases and all patients had complete occlusion of the shunt within three months.
Conclusion:
Device orientation was excellent in all cases. Device-related aortic insufficiency, tricuspid insufficiency or left ventricular dysfunction was not observed. One patient had embolisation of the device and another had complete heart block which required a permanent pacemaker implantation. The excellent short term results need to be confirmed over long-term follow-up.