Related Experiment Video
Updated: Mar 18, 2026

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Measurement of Retinal Vascular Caliber From Optical Coherence Tomography Phase Images
Klemens Fondi1, Gerold C Aschinger2, Ahmed M Bata1
1Department of Clinical Pharmacology, Medical University of Vienna, Vienna, Austria.
Purpose:
To compare retinal vessel calibers extracted from phase-sensitive optical coherence tomography (OCT) images with vessel calibers as obtained from the Retinal Vessel Analyzer (RVA).
Methods:
Data from previously published studies in 13 healthy subjects breathing room air (n = 214 vessels) and 7 subjects breathing 100% oxygen (n = 101 vessels) were used. Vessel calibers from OCT phase images were measured vertically along the optical axis by three independent graders. The data from RVA fundus images were corrected for magnification to obtain absolute values.
Results:
The average vessel diameter as obtained from OCT images during normoxia was lower than from RVA images (83.8 ± 28.2 microm versus 86.6 ± 28.0 microm, P < 0.001). The same phenomenon was observed during 100% oxygen breathing (OCT: 81.0 ± 22.4 microm, RVA: 85.5 ± 26.0 microm; P = 0.001). Although the agreement between the two methods was generally high, the difference in individual vessels could be as high as 40%. These differences were neither dependent on absolute vessel size nor preferably found in specific subjects. Interobserver differences between OCT evaluators were much lower than differences between the techniques.
Conclusions:
Extracting vessel calibers from OCT phase images may be an attractive approach to overcome some of the problems associated with fundus imaging. The source of differences in vessel caliber between the two methods remains to be investigated. In addition, it remains unclear whether OCT-based vessel caliber measurement is superior to fundus camera-based imaging in risk stratification for systemic or ocular disease. (ClinicalTrials.gov numbers, NCT00914407, NCT02531399.).
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
12:28Quantification of Vascular Parameters in Whole Mount Retinas of Mice with Non-Proliferative and Proliferative Retinopathies
Published on: March 12, 2022