Extinction measurement with open-path cavity ring-down technique of variable cavity length.
Optics Express
|July 14, 2016
Summary
A new variable cavity length open-path cavity ring down (OPCRD) technique precisely measures air
Area of Science:
- Atmospheric Optics
- Spectroscopy
- Environmental Science
Background:
- Optical extinction measurement is crucial for atmospheric studies.
- Existing methods often require closed-path cells, limiting real-time monitoring.
- A need exists for in-situ, absolute extinction measurements.
Purpose of the Study:
- To develop and validate a variable cavity length open-path cavity ring down (OPCRD) technique.
- To measure optical extinction (scattering and absorption) of air at 635 nm.
- To enable real-time environmental monitoring without sample cells.
Main Methods:
- Utilized a variable cavity length OPCRD setup.
- Experimentally determined ring-down times at different cavity lengths.
- Calculated total cavity loss dependence on cavity length.
Main Results:
- Established a linear relationship between total cavity loss and cavity length.
- Determined air extinction coefficients ranging from 10.46 to 84.19 Mm⁻¹ (ppm/m) at 635 nm.
- Demonstrated the technique's applicability in a laboratory environment.
Conclusions:
- The variable cavity length OPCRD technique provides accurate absolute extinction measurements.
- This method is suitable for real-time environmental monitoring of air optical properties.
- The technique eliminates the need for closed-path sample cells and background measurements.
Related Concept Videos
Atomic Emission Spectroscopy: Instrumentation
1.5K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.5K
Atomic Emission Spectroscopy: Lab
773
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
773
Standing Waves in a Cavity
1.6K
A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
1.6K
Atomic Absorption Spectroscopy: Lab
1.2K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.2K
Atomic Absorption Spectroscopy: Instrumentation
2.0K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
2.0K
Atomic Emission Spectroscopy: Interference
729
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
729