Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

5.3K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.3K
Distance Corrections01:15

Distance Corrections

348
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
348
Flame Photometry: Overview01:02

Flame Photometry: Overview

1.8K
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
1.8K
Calculating and Interpreting the Linear Correlation Coefficient01:11

Calculating and Interpreting the Linear Correlation Coefficient

8.4K
The correlation coefficient, r, developed by Karl Pearson in the early 1900s, is numerical and provides a measure of strength and direction of the linear association between the independent variable, x, and the dependent variable, y. Hence, it is also known as the Pearson product-moment correlation coefficient. It can be calculated using the following equation:
8.4K
Flame Photometry: Lab01:16

Flame Photometry: Lab

1.1K
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.1K
Temperature Measurement Sites01:14

Temperature Measurement Sites

3.9K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
3.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microbially driven microplastic degradation: From mining functional microbiota to enhancing remediation potential in diverse environments.

Journal of hazardous materials·2026
Same author

High mean arterial pressure after reperfusion is associated with unfavorable functional outcome in patients with acute ischemic stroke: A post hoc study of BAST trial.

Clinical neurology and neurosurgery·2026
Same author

Integration of BRAF V600E mutation with contrast-enhanced ultrasound parameters provides complementary diagnostic value for malignant thyroid nodules.

Frontiers in oncology·2026
Same author

Optical Bistability in Photonic Topological Hypercrystals and Its Applications in Photonic Neural Network.

Nanomaterials (Basel, Switzerland)·2026
Same author

Glucagon-like peptide-1: a critical link between gut microbiota dysbiosis and degenerative musculoskeletal diseases.

Gut microbes·2026
Same author

Deciphering transcriptome alterations in bone marrow immune cells at single-cell resolution under denosumab treatment.

International immunopharmacology·2026
Same journal

Denoising algorithm of Φ-OTDR systems based on adaptive fractional wavelet transform denoising.

Optics express·2026
Same journal

Millisecond photon-to-photon latency and high-speed volumetric projection system for optogenetics.

Optics express·2026
Same journal

Polarization-encoded coaxial structured light for high-precision 3D surface profilometry.

Optics express·2026
Same journal

Discrete freeform optical design based on collaborative optimization of point cloud and local normals.

Optics express·2026
Same journal

Ultrafast ghost imaging with 25 GHz speckle switching and wavelength-division multiplexing.

Optics express·2026
Same journal

Atomic vapor cells fabricated by femtosecond laser welding of standard-optical-quality glass.

Optics express·2026
See all related articles

Related Experiment Video

Updated: Mar 18, 2026

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
09:01

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings

Published on: April 16, 2017

8.2K

Accurate method for computing correlated color temperature.

Changjun Li, Guihua Cui, Manuel Melgosa

    Optics Express
    |July 14, 2016
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a new Newton method for accurately estimating correlated color temperature (CCT), improving upon previous approximate methods. The enhanced approach provides highly accurate CCT predictions for a wide range of light sources.

    More Related Videos

    Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
    09:46

    Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores

    Published on: August 19, 2013

    16.1K
    Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
    08:52

    Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere

    Published on: April 30, 2018

    8.8K

    Related Experiment Videos

    Last Updated: Mar 18, 2026

    High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
    09:01

    High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings

    Published on: April 16, 2017

    8.2K
    Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
    09:46

    Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores

    Published on: August 19, 2013

    16.1K
    Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
    08:52

    Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere

    Published on: April 30, 2018

    8.8K

    Area of Science:

    • Photometry and Colorimetry
    • Computational Optics
    • Lighting Science

    Background:

    • Estimating correlated color temperature (CCT) involves solving a nonlinear optimization problem.
    • Existing methods approximate the objective function, leading to limited accuracy and inconsistent predictions for light sources on the same isotemperature line.

    Purpose of the Study:

    • To develop a more accurate method for computing correlated color temperature (CCT).
    • To address the inaccuracies and inconsistencies of previous CCT estimation techniques.

    Main Methods:

    • Utilized the Newton method, requiring the first and second derivatives of the objective function.
    • Employed explicit objective function derivatives based on International Commission on Illumination (CIE) recommendations for tristimulus value computation (360 nm to 830 nm at 1 nm steps).
    • Combined the Newton method with Robertson's method for initial CCT estimation.

    Main Results:

    • Achieved highly accurate CCT predictions with errors below 0.0012 K.
    • Successfully computed CCT for light sources across a broad range, from 500 K to 10^6 K.

    Conclusions:

    • The proposed Newton method offers a significant improvement in CCT estimation accuracy.
    • This method provides reliable and precise CCT values, overcoming limitations of prior approaches.