Tailored loss discrimination in indefinite metamaterial-clad hollow-core fibers

Optics Express
|July 14, 2016
PubMed

Related Concept Videos

Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
430
Unsymmetric Loading of Thin-Walled Members01:23

Unsymmetric Loading of Thin-Walled Members

Thin-walled members with non-symmetrical cross-sections are vital to engineering structures, offering material efficiency and structural integrity. However, unsymmetrical loading on these members leads to complex stress distributions, resulting in simultaneous bending and twisting can cause deformation or structural failure. The interaction between bending and twisting requires detailed analysis to ensure structural resilience.
The concept of the shear center is crucial in countering the...
468
Unsymmetric Loading of Thin-Walled Members: Problem Solving01:07

Unsymmetric Loading of Thin-Walled Members: Problem Solving

The shear center of a channel section with uniform thickness, height, and width, is determined by computing the shear force in the member and calculating the moments of inertia of the sections.
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
573
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.8K