Related Experiment Video
Updated: Mar 17, 2026

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Gap junction modifiers regulate electrical activities of the sinoatrial node and pulmonary vein: Therapeutic
Chien-Jung Chang1, Chen-Chuan Cheng2, Yao-Chang Chen3
1Division of Cardiology, Tungs' Taichung MetroHarbor Hospital, Taichung, Taiwan.
Background:
Gap junction (GJ) dysfunctions predispose cardiac tissues to various arrhythmias. Sinoatrial node (SAN) and pulmonary veins (PVs) are closely related atrial dysrhythmia. This study evaluated whether GJ modifications modulate SAN and PVs electrical activities.
Methods:
Conventional microelectrodes were used to record action potentials in isolated rabbit SAN, PVs, and connected PV-SAN tissue preparations before and after heptanol (GJ inhibitor) and PQ1 (GJ enhancer) administration with and without isoproterenol. A whole-cell patch clamp was used to record the electrical activities before and after heptanol in single SAN and PV cardiomyocytes.
Results:
Heptanol (1, 3, and 10μM) reduced the spontaneous beating rates of isolated SAN preparations but not PVs. Heptanol (10μM) decelerated the SAN leading rhythm in the PV-SAN preparations and induced PV burst firings without (3 of 6, 50%) and with (6 of 6, 100%) isoproterenol (1μM). Heptanol (10μM) also reduced the spontaneous beating rates in single SAN cardiomyocyte, but not PV cardiomyocyte, with a decreased pacemaker current. PQ1 (50 and 500nM) treatment did not change the spontaneous beating rates in isolated SAN and PV preparations. In the connected PV-SAN preparations, PQ1 (500nM) did not induce any PV firing even having additional isoproterenol treatment (1μM). Moreover, PQ1 (500nM) prevented heptanol-induced electrical changes in SAN and PVs preparations.
Conclusion:
GJ dysfunction modulates SAN and PV electrical activity, which may contribute to atrial arrhythmogenesis. GJ enhancer has a therapeutic potential in SAN dysfunction and atrial arrhythmogenesis.
Related Concept Videos
Gap Junctions
Gap Junctions
G-Protein Gated Ion Channels
Sensory...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Electrophysiology of Normal Cardiac Rhythm