Contrast-enhanced μCT of the intervertebral disc: A comparison of anionic and cationic contrast agents for biochemical and morphological characterization
Related Experiment Video
Updated: Mar 17, 2026

Optical Sectioning and Visualization of the Intervertebral Disc from Embryonic Development to Degeneration
Published on: July 8, 2021
Michael D Newton1, Samantha E Hartner1, Shannon Timmons2
1Orthopaedic Research Laboratory, Beaumont Health, 3811W Thirteen Mile Road, Royal Oak, Michigan, 48073.
Abstract:
The objective of this study was to quantify and compare the contrast-enhancing properties of the anionic contrast agent ioxaglate/Hexabrix, and cationic contrast agent CA4+ for biochemical and morphological characterization of the intervertebral disc (IVD) via μCT. Optimal contrast agent concentrations were determined by incubating rat lumbar IVDs in dilutions of Hexabrix-320 (20%, 30%, 40%, and 50%) and CA4+ (10, 20, 30, and 40 mg I/ml). μCT imaging was performed at 70 kVp, 114 μA, and 250 ms integration time, 12 μm voxel size. The kinetics of contrast enhancement were quantified with cumulative incubations for 0.5, 1, 2, 12, 16, 20, and 24 h using both agents. Agreement in morphological quantification was assessed via serial scans of the same IVDs. Correlation of attenuation to glycosaminoglycan (GAG) content was determined by enzymatic digestion of IVDs, subsequent μCT imaging, and GAG quantification via dimethylmethylene blue assay. Forty percent Hexabrix and 30 mg I/ml CA4+ were chosen as optimal concentrations. Hexabrix enabled greater delineation of the IVD from surrounding tissues, and CA4+ had the lowest uptake in surrounding soft tissue. Twenty-four hour incubation was sufficient for >99% equilibration of both agents. A high level of agreement was observed in the quantification of IVD volume (ICC = 0.951, r = 0.997) and height (ICC = 0.947, r = 0.991). Both agents exhibited strong linear correlations between μCT attenuation and GAG content (Hexabrix: r = -0.940; CA4+ : r = 0.887). Both agents enable biochemical and morphological quantification of the IVD via contrast-enhanced μCT and are effective tools for preclinical characterization. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1067-1075, 2017.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

