Related Experiment Video
Updated: Mar 17, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Multiple scattering mechanisms causing interference effects in the differential cross sections of H + D2 → HD(v' = 4,
Mahima Sneha1, Hong Gao1, Richard N Zare1
1Department of Chemistry, Stanford University, Stanford, California 94305, USA.
Abstract:
Differential cross sections (DCSs) for the H + D2 → HD(v' = 4, j') + D reaction at 3.26 eV collision energy have been measured using the photoloc technique, and the results have been compared with those from quantum and quasiclassical scattering calculations. The quantum mechanical DCSs are in good overall agreement with the experimental measurements. In common with previous results at 1.97 eV, clear interference patterns which appear as fingerlike structures have been found at 3.26 eV but in this case for vibrational states as high as v' = 4. The oscillatory structure is prominent for low rotational states and progressively disappears as j' increases. A detailed analysis, similar to that carried out at 1.97 eV, shows that the origin of these structures could be traced to interferences between well defined classical mechanisms. In addition, at this energy, we do not observe the anomalous positive j'-θ trend found for the v' = 4 manifold at lower collision energies, thus reinforcing our explanation that the anomalous distribution for HD(v' = 4, j') at 1.97 eV only takes place for those states associated with low product recoil energies.
More Related Videos
10:16Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
Published on: February 8, 2014
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Interference and Diffraction
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Atomic Emission Spectroscopy: Interference