3D Printing Model of a Patient's Specific Lumbar Vertebra
Published on: April 14, 2023
A Prototype Hybrid Gypsum-Based 3-Dimensional Printed Training Model for Computed Tomography-Guided Spinal Pain
Ramin Javan1, Mohit Bansal, Ardalan Tangestanipoor
1From the Department of Radiology, George Washington University Hospital, Washington, DC.
Abstract:
This article details design methodology of an anatomically realistic and accurate physical 3-dimensional model of the lumbosacral spine from computed tomography data utilizing 3-dimensional printing. This model is unique in that the radiodense bony lumbosacrum is reconstructed using gypsum, which because of its high calcium content allows for the appropriate imaging characteristics mimicking bone. The model allows trainees to become competent in needle placement for image-guided diagnostic and therapeutic procedures.