Enhancement of abdominal structures on MRI at 1.5 and 3 T: a retrospective intraindividual crossover comparison
Mamdoh AlObaidy1,2, Miguel Ramalho2, Fernanda Velloni2
1Department of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia.
Objective:
To quantitatively compare the extent of enhancement of abdominal structures on MRI in an intraindividual fashion at 1.5 and 3 T.
Methods:
HIPAA-compliant, retrospective, longitudinal, intraindividual, crossover study, with waived informed consent, of consecutive individuals scanned at both 1.5 and 3 T closed-bore magnets using gadobenate dimeglumine during different phases of enhancement at tightly controlled arterial phase timing. Quantitative ROI measurements and qualitative sub-phase arterial phase assignments were independently performed by two radiologists. Qualitative discrepancies were resolved by a senior radiologist.
Results:
Final population included 60 patients [41 female and 19 male; age, 49.35 ± 18.31 years (range 16-81); weight, 78.88 ± 20.3 kg (range 44.5-136)]. Similar enhancement peak patterns were noted at both field strengths. Interobserver agreement of quantitative evaluations was substantial. Significantly higher amplitudes of enhancement peaks were noted for all abdominal solid organs during all phases at 3 T, except for the pancreas (p = 0.17-0.30). Significantly higher amplitudes of enhancement peaks of the abdominal aorta at 1.5 T were noted.
Conclusion:
Similar peak patterns of enhancement for abdominal structures were observed at 1.5 and 3 T, with solid abdominal organs showing a higher percentage enhancement at 3 T, while unexpectedly higher aortic higher percentage enhancement was observed at 1.5 T.
Key Points:
• Similar enhancement peak patterns at both field strengths for studied abdominal structures. • Significantly higher percentage enhancement of most abdominal organs at 3 T. • Non-statistically significant trend of higher pancreatic percentage enhancement at 3 T. • Significantly lower abdominal aortic percentage enhancement at 3 T.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI