Related Experiment Video
Updated: Mar 17, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection
Philip Enders1, Friederike Schaub1, Werner Adler2
1Department of Ophthalmology, University Hospital of Cologne, Cologne, Germany.
Purpose:
To assess the performance of Bruch's membrane opening (BMO)-based spectral domain optical coherence tomography (SD-OCT) of the optic nerve head for glaucoma detection in microdiscs in comparison with confocal scanning laser tomography (CSLT).
Design:
Retrospective cohort study.
Methods:
82 eyes of 82 patients with disc size <1.63 mm2 underwent SD-OCT and CSLT measurements, visual field testing and clinical examination. BMO-based minimal rim width (BMO-MRW), retinal nerve fibre layer thickness (RNFLT) in SD-OCT and rim area measured in CSLT were compared and correlated with visual field defects.
Results:
51 patients with glaucoma, 11 patients with ocular hypertension (OHT) and 20 healthy controls had a mean disc area of 1.36±0.19 mm2 in CSLT, and BMO area was 1.45±0.22 mm2 (r=0.17; p=0.12). In patients with glaucoma, visual field mean defect was -7.5±6.7 dB. Global BMO-MRW correlated better with visual field function (Spearman's r=0.65; p<0.001) than RNFLT (r=0.58; p≤0.001) and CSLT rim area (r=0.47; p=0.004). BMO-MRW significantly deteriorated with progressive visual field loss (p<0.001). In receiver operating characteristic analysis, sensitivity of BMO-MRW was 68.6% at 95% specificity (area under curve (AUC)=0.87), similar to sensitivity of RNFLT (66.4%; AUC=0.81). Performance of CSLT rim area was significantly worse (AUC=0.70, p=0.008). In healthy controls, mean BMO-MRW was 344.3±64.1 µm, mean RNFLT 78.0±11.3 µm and CSLT mean rim area 1.07±0.18 mm2.
Conclusions:
In small optic discs, BMO-MRW and peripapillary RNFLT (OCT) have similar sensitivity to discriminate patients with glaucoma from normal controls; both exceed CSLT rim area in diagnostic power. In glaucomatous patients, BMO-MRW correlates strongest with visual field function.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
06:19In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
Published on: November 11, 2017
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment