Related Experiment Video
Updated: Aug 11, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Comparative analysis of quantitative gastric emptying indices and power-exponential modelling of gastric emptying
1Department of Gastroenterology, Silesian School of Medicine, Katowice, Poland.
Abstract:
A comparative study was undertaken on the problems of choosing a reliable measure of gastric emptying (GE). The study was based on 218 GE measurements of a radiolabelled solid meal. Power-exponential fitting of GE curves was shown to provide an excellent mathematical approximation to experimental data - a coefficient of determination r2 greater than equal to 0.90 was obtained in the case of 96.3% GE curves. A range of indices was derived from the data, namely, the time to reach the maximum of a GE curve, the area under a GE curve, the mean transit time (and mean transit time during the ninety minutes of the examination), the emptying index, the GE half-time t 1/2 and the shape factor S. On the basis of between-subject variability (3.9% coefficient of variation) and reproducibility (coefficient of variation for paired examinations, CVp = 3.2%), the mean transit time calculated over the period of the GE study (MTT90) was found to be the best GE measure. The versatility of the power-exponential method was confirmed by the analysis of mathematical curves designed to mimic a range of real life emptying patterns, and the relationships between the derived parameters were also investigated.
More Related Videos
Related Concept Videos
Gastric Emptying
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Parametric Survival Analysis: Weibull and Exponential Methods
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...

