Evaluation of the Effect of Attenuation Correction by External CT in a Semiconductor SPECT
Taku Uchibe1, Masahiro Miyai, Nobuhiro Yata
1Department of Radiology, Shimane University Hospital.
Abstract:
The discovery of NM530c with a cadmium-zinc-telluride detector (CdZnTe-SPECT) is superior to the conventional Anger-type SPECT with a sodium-iodide detector (NaI-SPECT) in terms of sensitivity and spatial resolution. However, in the clinical example, even in CdZnTe-SPECT, a count decrease in myocardium due to the attenuation of the gamma ray is an issue. This study was conducted to evaluate the effect of computed tomography attenuation correction (CTAC) in CdZnTe-SPECT with the help of external CT. We evaluated the revision effect of uniformity, influence by the difference in attenuation distance, contrast ratio, an uptake rate using the heart phantom. As a result of the phantom studies, a good revision effect was obtained. In the clinical study, there was a statistical significant difference between the contrast ratio before and after CTAC in the inferior wall. In addition, the contrast ratio before and after CTAC in CdZnTe-SPECT image was equal to those of NaI-SPECT image. It was suggested that CTAC using external CT in CdZnTe-SPECT was clinically useful for inferior wall.
More Related Videos
08:46Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
10:42In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography CT and Light Microscopy LM Correlated with Scanning Electron Microscopy SEM
Published on: June 16, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...