Rational Design of a GFP-Based Fluorogenic Caspase Reporter for Imaging Apoptosis In Vivo
Tsz-Leung To1, Antonino Schepis2, Rubén Ruiz-González3
1Department of Pharmaceutical Chemistry, University of California, San Francisco, San Francisco, CA 94158, USA; Cardiovascular Research Institute, University of California, San Francisco, San Francisco, CA 94158, USA.
Abstract:
Fluorescence resonance energy transfer-based executioner caspase reporters using GFP are important tools for imaging apoptosis. While these reporters are useful for imaging apoptosis in cultured cells, their in vivo application has been handicapped by poor signal to noise. Here, we report the design and characterization of a GFP-based fluorogenic protease reporter, dubbed ZipGFP. ZipGFP-based TEV protease reporter increased fluorescence 10-fold after activation by protease. A ZipGFP-based executioner caspase reporter visualized apoptosis in live zebrafish embryos with spatiotemporal resolution. Thus, the ZipGFP-based caspase reporter may be useful for monitoring apoptosis during animal development and for designing reporters of proteases beyond the executioner caspases.