Related Experiment Video
Updated: Mar 17, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection
Ayla Campos do Lago1, Camila Marchioni2, Tássia Venga Mendes2
1Universidade Federal de São Carlos (UFSCar-SP), Departamento de Química, São Carlos, SP, Brazil.
Abstract:
This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L-1 and buffer concentration of 0.01 mol L-1, were adopted. The proposed method showed a linear response in the range of 0.081-10.0 μg L-1, limits detection and quantification of 0.024 and 0.081 μg L-1, respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min-1, and frequency of readings equal to 26 readings h-1 The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg-1), black tea (1.09 ± 0.15 μg kg-1), green tea (3.85 ± 0.13 μg kg-1), cigarette tobacco (38.27 ± 0.22 μg kg-1), and hair (0.35 ± 0.02 μg kg-1).
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Instrumentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...