Related Experiment Video
Updated: Mar 17, 2026

Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Preliminary Measures of Instructor Learning in Teaching Junctional Tourniquet Users
Background:
The objective of the present study was to assess the effect of instructor learning on student performance in use of junctional tourniquets.
Methods:
From a convenience sample of data available after another study, we used a manikin for assessment of control of bleeding from a right groin gunshot wound. Blood loss was measured by the instructor while training users. The data set represented a group of 30 persons taught one at a time. The first measure was a plot of mean blood loss volumes for the sequential users. The second measure was a plot of the cumulative sum (CUSUM) of mean blood loss (BL) volumes for users.
Results:
Mean blood loss trended down as the instructor gained experience with each newly instructed user. User performance continually improved as the instructor gained more experience with teaching. No plateau effect was observed within the 30 users. The CUSUM plot illustrated a turning point or cusp at the seventh user. The prior portion of the plot (users 1-7) had the greatest improvement; performance did not improve as much thereafter. The improvement after the seventh user was the only change detected in the instructor's trend of performance.
Conclusions:
The instructor's teaching experience appeared to directly affect user performance; in a model of junctional hemorrhage, the volume of blood loss from the manikin during junctional tourniquet placement was a useful metric of instructor learning. The CUSUM technique detected a small but meaningful change in trend where the instructor learning curve was greatest while working with the first seven users.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pre-Procedural Guidelines for Assessing Blood Pressure

