Related Experiment Video
Updated: Mar 17, 2026

A New Approach for the Comparative Analysis of Multiprotein Complexes Based on 15N Metabolic Labeling and Quantitative Mass Spectrometry
Published on: March 13, 2014
On the Statistical Significance of Compressed Ratios in Isobaric Labeling: A Cross-Platform Comparison
Ana Martinez-Val1, Fernando Garcia1, Pilar Ximénez-Embún1
1ProteoRed-ISCIII. Proteomics Unit, Spanish National Cancer Research Centre (CNIO), 28029 Madrid, Spain.
Abstract:
Isobaric labeling is gaining popularity in proteomics due to its multiplexing capacity. However, copeptide fragmentation introduces a bias that undermines its accuracy. Several strategies have been shown to partially and, in some cases, completely solve this issue. However, it is still not clear how ratio compression affects the ability to identify a protein's change of abundance as statistically significant. Here, by using the "two proteomes" approach (E. coli lysates with fixed 2.5 ratios in the presence or absence of human lysates acting as the background interference) and manipulating isolation width values, we were able to model isobaric data with different levels of accuracy and precision in three types of mass spectrometers: LTQ Orbitrap Velos, Impact, and Q Exactive. We determined the influence of these variables on the statistical significance of the distorted ratios and compared them to the ratios measured without impurities. Our results confirm previous findings1-4 regarding the importance of optimizing acquisition parameters in each instrument in order to minimize interference without compromising precision and identification. We also show that, under these experimental conditions, the inclusion of a second replicate increases statistical sensitivity 2-3-fold and counterbalances to a large extent the issue of ratio compression.
More Related Videos
09:06Measurement of the Compressibility of Cell and Nucleus Based on Acoustofluidic Microdevice
Published on: July 14, 2022
10:16Design and Operation of a Continuous 13C and 15N Labeling Chamber for Uniform or Differential, Metabolic and Structural, Plant Isotope Labeling
Published on: January 16, 2014
Related Concept Videos
Molecular Comparison of Gases, Liquids, and Solids
Bioequivalence Data: Statistical Interpretation
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...