Binding Isotherms and Time Courses Readily from Magnetic Resonance

Jia Xu1, Steven R Van Doren1

  • 1Department of Biochemistry, University of Missouri , 117 Schweitzer Hall, Columbia, Missouri 65211, United States.

Analytical Chemistry
|July 27, 2016
PubMed
Summary

Principal component analysis (PCA) directly analyzes complex 2D NMR spectra to extract binding isotherms without peak picking. This method accurately captures binding dynamics across various exchange regimes and data types.

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.2K
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.6K
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.7K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.3K