Related Experiment Video
Updated: Mar 17, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Development of a validated UPLC-MS/MS method for PK/PD analysis of SYL930 and its two major metabolites in dogs
Manman Zhao1, Jiaqi Mi1, Xin Liu1
1Department of Drug Metabolism, Beijing Key Laboratory of Non-Clinical Drug Metabolism and PK/PD Study, Beijing Key Laboratory of Active Substances Discovery and Drug Ability Evaluation, State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Abstract:
A sensitive and specific UPLC-MS/MS method was developed and validated for the simultaneous determination of 2-amino-2-(2-(4'-(2-propyloxazol-4-yl)-[1,1'-biphenyl]-4-yl)ethyl)propane-1,3-diol (SYL930), phosphorylated metabolite (SYL930-P) and hydroxylated metabolite (SYL930-M) in dog blood using SYL927 and SYL927-P, analogues of SYL930, as the internal standards. Analytes were extracted with protein precipitation followed by chromatographic separation on a ZorbaxSB-C18 column (3.5 μm, 2.1 × 100 mm) with a gradient elution of methanol-water containing 0.1% formic acid (v/v). A triple quadrupole tandem mass spectrometer operating in the positive electrospray ionization mode was used to detect SYL930, SYL930-P, SYL930-M and IS transitions of 381.2 → 364.2, 461.2 → 334.2, 397.3 → 380.3, 367.1 → 350.4 and 447.5 → 320.2, respectively. The linear calibration curves for SYL930, SYL930-P and SYL930-M were 0.5-500, 0.2-100 and 0.5-100 ng/mL, respectively (r2 > 0.99). The intra-day and inter-day precisions (RSD, %) of analytes did not exceed 9.16% except for low QCs (≤16.22%), and the accuracy (RE, %) ranged from -14 to 11.4%. The mean recoveries for SYL930, SYL930-P and SYL930-M in dog blood were 85.13-107.94, 73.84-80.08 and 85.64-95.44%, respectively. The validated method was successfully applied to pharmacokinetic and PK/PD studies of SYL930 and its two major metabolites in dogs after an oral administration of SYL930.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013