Radiation dose measurements during kilovoltage-cone beam computed tomography imaging in radiotherapy
A Sathish Kumar1, I Rabi Raja Singh1, Sunil Dutt Sharma2
1Department of Radiotherapy, Christian Medical College, Vellore, Tamil Nadu, India.
Objective:
The use of image guidance during radiotherapy for accurate localization and setup has become the standard care of practice in radiotherapy. This mostly involves the use of kilovoltage-cone beam computed tomography (kV-CBCT) for verification of patient setup on the first few days and on a weekly basis. Some protocols require this to be performed daily and also before and after the treatment. Though the radiation due to this kV-CBCT is small, the repeated use could deliver a dose that could increase the probability of the stochastic effect. The main purpose of this work is to measure radiation dose during image guidance with kV-CBCT.
Materials And Methods:
In this work, we have attempted to measure the dose during kV-CBCT for different sites both on a humanoid phantom and on patients undergoing image-guided radiotherapy with MOSFETs calibrated against an ion chamber.
Results:
The dose measurement on patients during kV-CBCT resulted in mean doses of 0.19 and 0.3 cGy to the ipsilateral and contralateral eyes, 0.625 and 1.097 cGy to the surface of the ipsilateral and contralateral breasts, and 3.01 cGy to the surface of the pelvis.
Conclusion:
Radiation dose to the eye, breast, and the surface of the pelvis have been arrived at during CBCT. The doses measured on patients agreed closely with those measured on humanoid phantom and with published values.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Imaging Studies III: Computed Tomography
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...