Related Experiment Video
Updated: Mar 17, 2026

Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
Evaluation of anterior segment parameters in patients with pseudoexfoliation syndrome using Scheimpflug imaging
Alime Gunes1, Musa Yigit1, Levent Tok1
1Department of Ophthalmology, Süleyman Demirel University Faculty of Medicine, Isparta, Turkey.
Purpose:
To evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) using Scheimpflug imaging.
Methods:
Forty-three PXS patients and 43 healthy control subjects were included in this cross-sectional study. All participants underwent a detailed ophthalmologic examination. Anterior segment parameters were measured using a Scheimpflug system.
Results:
Considering the PXS and control groups, the mean corneal thicknesses at the apex point (536 ± 31 and 560 ± 31 µm, respectively, p=0.001), at the center of the pupil (534 ± 31 and 558 ± 33 µm, respectively, p=0.001), and at the thinnest point (528 ± 30 and 546 ± 27 µm, respectively, p=0.005) were significantly thinner in PXS patients. Visual acuity was significantly lower (0.52 ± 0.37 versus 0.88 ± 0.23, p<0.001) and axial length was significantly longer (23.9 ± 0.70 mm versus 23.2 ± 0.90 mm, p=0.001) in the PXS eyes than in the control eyes. There were no statistically significant differences in the mean values of keratometry, anterior chamber angle, anterior chamber depth, corneal volume, and anterior chamber volume between the PXS and control eyes.
Conclusions:
The patients with PXS had thinner corneas, worse visual acuity, and longer axial length compared with those in the healthy controls.