Related Experiment Video
Updated: Mar 17, 2026

An Ultra-clean Multilayer Apparatus for Collecting Size Fractionated Marine Plankton and Suspended Particles
Published on: April 19, 2018
Analysis of the elemental composition of marine litter by field-portable-XRF
Andrew Turner1, Kevin R Solman1
1School of Geography, Earth and Environmental Sciences, Plymouth University, Drake Circus, Plymouth PL4 8AA, UK.
Abstract:
Marine litter represents a pervasive environmental problem that poses direct threats to wildlife and habitats. Indirectly, litter can also act as a vehicle for the exposure and bioaccumulation of chemicals that are associated with manufactured or processed solids. In this study, we describe the use of a Niton field-portable-x-ray fluorescence (FP-XRF) spectrometer to determine the content of 17 elements in beached plastics, foams, ropes and painted items. The instrument was used in a 'plastics' mode configured for complex, low density materials, and employed a thickness correction algorithm to account for varying sample depth. Accuracy was evaluated by analysing two reference polyethylene discs and was better than 15% for all elements that had been artificially impregnated into the polymer. Regarding the litter samples, limits of detection for a 120s counting time varied between the different material categories and among the elements but were generally lowest for plastics and painted items with median concentrations of less than 10μgg(-1) for As, Bi, Br, Cr, Hg, Ni, Pb, Se and Zn. Concentrations returned by the XRF were highly sensitive to the thickness correction applied for certain elements (Ba, Cl, Cr, Cu, Fe, Sb, Ti, Zn) in all matrices tested, indicating that accurate measurement and application of the correct thickness is critical for acquiring reliable results. An independent measure of the elemental content of selected samples by ICP spectrometry following acid digestion returned concentrations that were significantly correlated with those returned by the XRF, and with an overall slope of [XRF]/[ICP]=0.85. Within the FP-XRF operating conditions, Cl, Cr, Fe, Ti and Zn were detected in more than 50% and Hg and Se in less than 1% of the 376 litter samples analysed. Significant from an environmental perspective were concentrations of the hazardous elements, Cd, Br and Pb, that exceeded several thousand μgg(-1) in many cases.
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...

