Related Experiment Video
Updated: Mar 17, 2026

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Acid retardation method in analysis of strongly acidic solutions by inductively coupled plasma mass-spectrometry
I F Seregina1, O A Perevoznik1, M A Bolshov2
1Chemistry Department, Analytical Chemistry Division, Lomonosov Moscow State University, 1-3 Leninskie Gory, 119991 Moscow, Russian Federation.
Abstract:
Acid retardation on the sorbents as a technique for reduction of the acidity of the solutions prior to their analysis by inductively coupled plasma mass spectrometry was proposed and investigated. The proposed scheme provides substantial separation of the analytes and nitric acid, which allows direct introduction of the eluates in plasma without dilution. Two sorbents were examined - AV-17 anion-exchange resin and the Stirosorb 584 sorbent. Sorption and desorption of 38 elements on these sorbents were investigated. The efficiencies of the REEs' sorption on the anion-exchange and neutral sorbents were compared. The higher efficiency of the REEs and HNO3 separation was revealed for the neutral Stirosorb 584 sorbent. It was also found that most elements come out quantitatively of the column filled with the AV-17 resin after pumping 2-4mL of the solution. Wherein, the concentration of nitric acid decreased by 20 times. The anomalous behaviour of Ag, Pb, Th and U on the AV-17 resin was found. These analytes were eluted only after pumping 4 column volumes of deionized water. Na, K, Fe, Al and Li in concentrations within (50-1000mgL(-1)) range did not affect the recovery of REEs. The potential of ARM technique was demonstrate by the analysis of puriss. HNO3 and silverware. ARM enables to avoid dilution of highly acidic solutions prior to their introduction in ICP-MS.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....

