Predictors of internal mammary vessel diameter: A computed tomographic angiography-assisted anatomic analysis
Julia A Cook1, Sunil S Tholpady2, Arash Momeni3
1Division of Plastic & Reconstructive Surgery, Indiana University School of Medicine, 545 Barnhill Drive, #232, Indianapolis, IN 46202, United States.
Abstract:
The internal mammary vessels are the most common recipient vessels in free flap breast reconstruction. The literature on internal mammary vascular anatomy is limited by small sample sizes, cadaveric studies, or intraoperative changes. The purpose of this study is to analyze internal mammary anatomy using computed tomographic angiography. A retrospective review of 110 consecutive computed tomographic angiography studies of female patients was performed. Measurements of vessel caliber, distance of internal mammary vessels to sternum, location of internal mammary vein bifurcation, intercostal space height, and chest width were analyzed. Patient demographics and comorbidities were reviewed. The right internal mammary artery and vein were larger than the left in all intercostal spaces (p = 0.02 and p < 0.001, respectively). A significant correlation was found between both skeletal chest width and body mass index with internal mammary vessel caliber at the third intercostal space (p ≤ 0.02). The internal mammary vein bifurcated at the third intercostal space bilaterally, 4.3 and 1.2 mm caudal to the third rib on the right and left sides, respectively. The third intercostal space was <1.5 cm in 25% of patients. Understanding the anatomy, bifurcation, and caliber of internal mammary vessels can aid preoperative planning of autologous, free flap breast reconstruction. On average, the internal mammary vein bifurcates at the third intercostal space; patients with larger chest widths and body mass index had larger caliber internal mammary vessels, and 25% of patients had third intercostal space <1.5 cm and, thus, may not be suitable candidates for rib-sparing techniques.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
10:25Author Spotlight: Integrating High-Resolution Intravital Imaging and MRI to Enhance Stereotactic Body Radiation Therapy Planning
Published on: April 12, 2024