Related Experiment Video
Updated: Mar 17, 2026

Separation of Aldehydes and Reactive Ketones from Mixtures Using a Bisulfite Extraction Protocol
Published on: April 2, 2018
Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycles in reversed-phase liquid
Walter B Wilson1, Lane C Sander1, Miren Lopez de Alda1
1Chemical Sciences Division, Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899, United States.
Abstract:
Retention indices for 79 alkyl-substituted polycyclic aromatic sulfur heterocycles (PASHs) were determined by using reversed-phase liquid chromatography (LC) on a monomeric and polymeric octadecylsilane (C18) stationary phase. Molecular shape parameters [length, breadth, thickness (T), and length-to-breadth ratio (L/B)] were calculated for all the compounds studied. Based on separations of isomeric methylated polycyclic aromatic hydrocarbons on polymeric C18 phases, alkyl-substituted PASHs are expected to elute based on increasing L/B ratios. However, the correlation coefficients had a wide range of values from r=0.43 to r=0.93. Several structural features besides L/B ratios were identified to play an important role in the separation mechanism of PASHs on polymeric C18 phases. First, the location of the sulfur atom in a bay-like-region results in alkylated-PASHs being more retentive than non-bay-like-region alkylated-PASHs, and they elute later than expected based on L/B value. Second, the placement of the alkyl group in the k region of the structure resulted in a later elution than predicted by L/B. Third, highly nonplanar methyl-PASHs (i.e., 1-Me and 11-MeBbN12T) elute prior to the parent PASH (BbN12T).
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chirality at Nitrogen, Phosphorus, and Sulfur
A consequence of chirality is the need for enantiomeric resolution. While this is theoretically possible for all...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...