Related Experiment Video
Updated: Mar 17, 2026

Improved Polydimethylsiloxane (PDMS) Double Casting via Silicone Oil Treatment for Densely Packed Microstructure Replication
Published on: July 18, 2025
Handling of Polyvinylsiloxane Versus Polyether for Implant Impressions
Purpose:
This study compared polyvinylsiloxane with polyether in handling dental impressions.
Materials And Methods:
Each participant (N = 39) made four impressions, each a combination of pickup and reseating techniques with polyether or polyvinylsiloxane, of one implant cast representing a specific clinical situation (tooth gaps, limited residual dentition, or edentulous jaw). Handling of impressions was subsequently rated by using a 12-item questionnaire with 100-mm visual analog scales.
Results:
While mean satisfaction scores were higher for polyvinylsiloxane than for polyether (69.5/63.0, P < .001), differences among subgroups were statistically significant only for pickup technique, limited residual dentition, and edentulous jaw.
Conclusion:
Implant impressions made with polyvinylsiloxane using a pickup technique seem to be the best option for most clinical situations.