Gas chromatography fractionation platform featuring parallel flame-ionization detection and continuous
Willem Jonker1, Bas Clarijs1, Susannah L de Witte2
1Vrije Universiteit Amsterdam, Division of BioAnalytical Chemistry, De Boelelaan 1108, 1081 HZ, Amsterdam, The Netherlands.
Abstract:
Gas chromatography (GC) is a superior separation technique for many compounds. However, fractionation of a GC eluate for analyte isolation and/or post-column off-line analysis is not straightforward, and existing platforms are limited in the number of fractions that can be collected. Moreover, aerosol formation may cause serious analyte losses. Previously, our group has developed a platform that resolved these limitations of GC fractionation by post-column infusion of a trap solvent prior to continuous small-volume fraction collection in a 96-wells plate (Pieke et al., 2013 [17]). Still, this GC fractionation set-up lacked a chemical detector for the on-line recording of chromatograms, and the introduction of trap solvent resulted in extensive peak broadening for late-eluting compounds. This paper reports advancements to the fractionation platform allowing flame ionization detection (FID) parallel to high-resolution collection of a full GC chromatograms in up to 384 nanofractions of 7s each. To this end, a post-column split was incorporated which directs part of the eluate towards FID. Furthermore, a solvent heating device was developed for stable delivery of preheated/vaporized trap solvent, which significantly reduced band broadening by post-column infusion. In order to achieve optimal analyte trapping, several solvents were tested at different flow rates. The repeatability of the optimized GC fraction collection process was assessed demonstrating the possibility of up-concentration of isolated analytes by repetitive analyses of the same sample. The feasibility of the improved GC fractionation platform for bioactivity screening of toxic compounds was studied by the analysis of a mixture of test pesticides, which after fractionation were subjected to a post-column acetylcholinesterase (AChE) assay. Fractions showing AChE inhibition could be unambiguously correlated with peaks from the parallel-recorded FID chromatogram.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...