Related Experiment Video
Updated: Mar 16, 2026

Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
An interface for online coupling capillary electrophoresis to dielectric barrier discharge ionization mass
Yiding Zhang1, Wanpeng Ai1, Yu Bai2
1Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
Abstract:
The online combination of capillary electrophoresis (CE) with mass spectrometry (MS) has long been desired for the capability of direct and simultaneous separation and detection with high efficiency, accuracy, and throughput. In this work, a novel CE-MS interface was developed, using dielectric barrier discharge ionization (DBDI). The interface employed a spray tip with a coaxial three-layer structure, into which the CE sample solution, the sheath liquid, and the nebulizing gas were introduced. The spray tip was put between the DBDI outlet and the MS inlet, thus the CE sample solution could be blended with the sheath liquid, then nebulized. The nebulized sample could be ionized by DBDI, and finally analyzed by MS. The key parameters of the interface were optimized. Then, proof-of-concept experiments separating and detecting the mixture of metronidazole and acetaminophen solutions were conducted. The results showed high separation efficiency, low time consumption, high reproducibility, and convenience in operation. In addition, the interface exhibited a high tolerance of non-volatile salts and surfactants, which would be widely used in CE analyses. All of these results demonstrated that the newly developed CE-DBDI-MS interface could be successfully used in CE-MS studies, and could be further utilized in multiple areas involving efficient separation and detection.
More Related Videos
10:05Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Electrophoresis: Overview
There...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...