Related Experiment Video
Updated: Mar 16, 2026

Fluorescence detection methods for microfluidic droplet platforms
Published on: December 10, 2011
Investigation of fluorescence methods for rapid detection of municipal wastewater impact on drinking water sources
Nicolas M Peleato1, Raymond L Legge2, Robert C Andrews1
1Department of Civil Engineering, University of Toronto, 35 St. George St., Toronto, Ontario M5S 1A4, Canada.
Abstract:
Fluorescence spectroscopy as a means to detect low levels of treated wastewater impact on two source waters was investigated using effluents from five wastewater facilities. To identify how best to interpret the fluorescence excitation-emission matrices (EEMs) for detecting the presence of wastewater, several feature selection and classification methods were compared. An expert supervised regional integration approach was used based on previously identified features which distinguish biologically processed organic matter including protein-like fluorescence and the ratio of protein to humic-like fluorescence. Use of nicotinamide adenine dinucleotide-like (NADH) fluorescence was found to result in higher linear correlations for low levels of wastewater presence. Parallel factors analysis (PARAFAC) was also applied to contrast an unsupervised multiway approach to identify underlying fluorescing components. A humic-like component attributed to reduced semiquinone-like structures was found to best correlate with wastewater presence. These fluorescent features were used to classify, by volume, low (0.1-0.5%), medium (1-2%), and high (5-15%) levels by applying support vector machines (SVMs) and logistic regression. The ability of SVMs to utilize high-dimensional input data without prior feature selection was demonstrated through their performance when considering full unprocessed EEMs (66.7% accuracy). The observed high classification accuracies are encouraging when considering implementation of fluorescence spectroscopy as a water quality monitoring tool. Furthermore, the use of SVMs for classification of fluorescence data presents itself as a promising novel approach by directly utilizing the high-dimensional EEMs.
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
10:57Experimental Protocol for Detecting Cyanobacteria in Liquid and Solid Samples with an Antibody Microarray Chip
Published on: February 7, 2017