Related Experiment Video
Updated: Mar 16, 2026

Intratracheal Administration of Dry Powder Formulation in Mice
Published on: July 25, 2020
Powder dispersion mechanisms within a dry powder inhaler using microscale particle image velocimetry
Xiang Kou1, Steven T Wereley2, Paul W S Heng1
1Department of Pharmacy, National University of Singapore, Singapore.
Abstract:
The goal of this work was to evaluate the ability of Particle Image Velocimetry (PIV) to visually assess dry powder dispersion within an inhaler. Herein, the study reports particle movement characterization of entrained low-micron particles within an inhaler to further scheme of potential mechanisms. Carrier based DPI formulations were prepared and placed in a transparent model Rotahaler® chamber for the aerosolization experiments. Then using the PIV, a high-speed camera, the dried powder dispersion was directly observed and analyzed for all, neat, binary and ternary systems. Powder dispersion mechanisms proposed include drag force, impact with obstacle and particle-particle collision; these different mechanisms depended on the powder flow properties. A revised ratio of aerodynamic response time (τA) to the mean time between collisions (τC) was found to be 6.8 indicating that particle collisions were of strong influence to particle dispersion. With image analysis techniques, visualization of particle flow pattern and collision regions was possible; suggesting that the various mechanisms proposed did govern the powder dispersion.
Related Concept Videos
Inhaled Medications
In Vitro Drug Dissolution: Compendial Testing Models II